NITROGEN BALANCES FOR SEVERAL ORGANIC SMOG SYSTEMS IN OUTDOOR SMOG SYSTEMS.

Kenneth G. Sexton, Harvey E. Jeffries

Research output: Contribution to journalArticle

  • 1 Citations

Abstract

This paper presents the results of several experiments performed in the UNC outdoor smog chamber where nitrogen balances were performed utilizing the measurements of NO, NO//2, PAN, and HNO//3. NO, NO//2, and NO//x were measured by chemiluminescence and NO//2 by the Saltzman technique. PAN was measured with a gas chromatograph equipped with an electron capture detector, utilizing a glass column of 5% Carbowax 800 on Chromosorb.

LanguageEnglish (US)
Journal[No source information available]
Volume1
StatePublished - Jan 1 2017

Fingerprint

Chemiluminescence
Nitrogen
Detectors
Glass
Electrons
Gases
Experiments

ASJC Scopus subject areas

  • Engineering(all)

Cite this

NITROGEN BALANCES FOR SEVERAL ORGANIC SMOG SYSTEMS IN OUTDOOR SMOG SYSTEMS. / Sexton, Kenneth G.; Jeffries, Harvey E.

In: [No source information available], Vol. 1, 01.01.2017.

Research output: Contribution to journalArticle

@article{7f67f9e7f4a64d44b9d3c41950c7abab,
title = "NITROGEN BALANCES FOR SEVERAL ORGANIC SMOG SYSTEMS IN OUTDOOR SMOG SYSTEMS.",
abstract = "This paper presents the results of several experiments performed in the UNC outdoor smog chamber where nitrogen balances were performed utilizing the measurements of NO, NO//2, PAN, and HNO//3. NO, NO//2, and NO//x were measured by chemiluminescence and NO//2 by the Saltzman technique. PAN was measured with a gas chromatograph equipped with an electron capture detector, utilizing a glass column of 5\{%} Carbowax 800 on Chromosorb.",
author = "Sexton, {Kenneth G.} and Jeffries, {Harvey E.}",
year = "2017",
month = "1",
day = "1",
language = "English (US)",
volume = "1",
journal = "[No source information available]",
issn = "0099-4081",

}

TY - JOUR

T1 - NITROGEN BALANCES FOR SEVERAL ORGANIC SMOG SYSTEMS IN OUTDOOR SMOG SYSTEMS.

AU - Sexton,Kenneth G.

AU - Jeffries,Harvey E.

PY - 2017/1/1

Y1 - 2017/1/1

N2 - This paper presents the results of several experiments performed in the UNC outdoor smog chamber where nitrogen balances were performed utilizing the measurements of NO, NO//2, PAN, and HNO//3. NO, NO//2, and NO//x were measured by chemiluminescence and NO//2 by the Saltzman technique. PAN was measured with a gas chromatograph equipped with an electron capture detector, utilizing a glass column of 5% Carbowax 800 on Chromosorb.

AB - This paper presents the results of several experiments performed in the UNC outdoor smog chamber where nitrogen balances were performed utilizing the measurements of NO, NO//2, PAN, and HNO//3. NO, NO//2, and NO//x were measured by chemiluminescence and NO//2 by the Saltzman technique. PAN was measured with a gas chromatograph equipped with an electron capture detector, utilizing a glass column of 5% Carbowax 800 on Chromosorb.

UR - http://www.scopus.com/inward/record.url?scp=0018281884&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0018281884&partnerID=8YFLogxK

M3 - Article

VL - 1

JO - [No source information available]

T2 - [No source information available]

JF - [No source information available]

SN - 0099-4081

ER -